| Datasheets.org.uk - 100 Million Datasheets from 7500 Manufacturers. |
JUMO PROCESS CONTROL INC. Chase, Suite Coatesville 19320, Phone: 610-3
Top Searches for this datasheetPotentiometer TYPE L1 LINEAR LAW* - Potentiometer TYPE L1 LINEAR LAW* Potentiometer TYPE L1* - Potentiometer TYPE L1* logoprint - logoprint calibration of jumo logoprint - calibration of jumo logoprint 24v 8 channel Relay - 24v 8 channel Relay JUMO Instrument Ltd. JUMO House Temple Bank, Riverway Harlow, Essex 2TT, Phone: 1279 635533 Fax: 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO PROCESS CONTROL INC. Chase, Suite Coatesville 19320, Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-mail: info@JumoUSA.com Internet: www.JumoUSA.com Data Sheet 95.4012 Page 1/12 Printing recorder with text printing 24-character dot-matrix display Brief description LOGOPRINT recorder family consists printing recorders, LOGOPRINT LOGOPRINT junior. LOGOPRINT (Type 954012) printing recorder equipped with (optionally) measurement inputs, which electrically isolated from another. evaluation measurement traces printing recorder assisted extensive text printing. recorder programmed either using keys front instrument through setup program. Thermocouples, resistance thermometers, resistance transmitters, potentiometers, voltages currents (standard signals) possible input signals. appropriate linearizations carried automatically, also adapted customer-specific linearizations with help setup program. Further outstanding features LOGOPRINT 500, which already included basic version, four open-collector outputs signaling infringements limits faults, eight event traces, well peak value recording. color assignments (measurement traces texts) freely programmable setup program, which available accessory. LOGOPRINT junior (Type 954013) This recorder equipped with measurement inputs, which electrically isolated from another. also support evaluation measurement traces with printed text (limited). Programming only possible keys. Voltages currents (standard signals) possible input signals. There open-collector outputs, event traces, peak value recording extra codes. Type 954012 Overview functions Type 954012 Analog inputs (configurable isolated) inputs for: thermocouples resistance thermometers resistance transmitters potentiometers voltage current logic inputs Outputs available extra code open-collector outputs available extra code: interface relay outputs supply 2-wire transmitter Recording measurement traces text printing event traces Setup interface RS422/RS485 interface Supply voltage configuration parameter setting extra code data transfer from recorder 240V +10/-15% 63Hz AC/DC 63Hz available available 240V +10/-15% 63Hz AC/DC 63Hz measurement traces text printing (limited) available available Type 954013 inputs for: voltage current Type 954013 Features Type 954012 Limit monitoring Event traces Four open-collector outputs Peak value recording Extensive text printing Statistics (report) with minimum, maximum mean values Event- time-controlled chart speed Math logic module setup program required) Universal chart cassette 06.02/00355277 JUCHHEIM GmbH 36035 Fulda, Germany Data Sheet 95.4012 Page 2/12 Technical data Thermocouple input (Type 954012) Designation Fe-Con Fe-Con Cu-Con Cu-Con NiCr-Ni NiCr-Con NiCrSi-NiSi Pt10Rh-Pt Pt13Rh-Pt Pt30Rh-Pt6Rh Shortest span Range start/end Cold junction Cold junction accuracy (internal) Cold junction temperature (external) Measurement time Input filter Features linearization accuracy refers maximum span. linearization accuracy reduced shorter spans. invalid since 1995 Range -200 -210 -200 -270 -270 -270 -270 900°C +1200°C 600°C 400°C +1372°C +1000°C +1300°C +1768°C +1768°C 1820°C Linearisation accuracy1 ±0.2% ±0.2% above -200°C ±0.3% ±0.5% above -200°C ±0.2% above -150°C ±0.2% above -200°C ±0.2% above -150°C ±0.5% above ±0.5% above ±0.5% above 500°C 100°C 500°C 7102 Types Types freely programmable within limits 0.1°C steps internal thermostat external constant +100°C, adjustable through setup software channels 2sec; channels 4sec order digital filter; filter constant adjustable from 50.0sec also programmable customer-specific linearizations Resistance thermometer input (Type 954012) Connection 2/3-wire 2/3-wire 4-wire 4-wire 2/3-wire 2/3-wire 4-wire 4-wire 2/3-wire 2/3-wire 4-wire 4-wire 2/3-wire 2/3-wire 4-wire 4-wire 2/3-wire 2/3-wire 4-wire 4-wire Range -200 +250°C -200 +850°C -200 +250°C -200 +850°C -200 +260°C -200 +649°C -200 +260°C -200 +649°C -200 +150°C -200 +850°C -200 +150°C -200 +850°C -200 +250°C -200 +850°C -200 +250°C -200 +850°C +125°C +180°C +125°C +180°C Linearisation accuracy ±0.6°C ±1.0°C ±0.5°C ±0.8°C ±0.6°C ±1.0°C ±0.5°C ±0.8°C ±0.6°C ±1.0°C ±0.5°C ±0.8°C ±0.6°C ±1.0°C ±0.5°C ±0.8°C ±0.6°C ±1.0°C ±0.5°C ±0.8°C 15°C Meas. current 500µA 250µA 500µA 250µA 500µA 250µA 500µA 250µA 250µA 250µA 250µA 250µA 500µA 250µA 500µA 250µA 500µA 250µA 500µA 250µA 1000 Connection type Shortest span Probe lead resistance 4-wire circuit max. core 4-wire circuit max. core 3-wire circuit 260°C max. core 2-wire 3-wire circuit freely programmable within limits 0.1°C steps channels 2sec; channels 4sec order digital filter; filter constant adjustable from 50sec also programmable customer-specific linearizations Range start/end Measurement time Input filter Features 06.02/00355277 JUCHHEIM GmbH 36035 Fulda, Germany Data Sheet 95.4012 Page 3/12 Resistance transmitter potentiometer input (Type 954012) Range Accuracy 2000 4000 Connection type Shortest span Probe lead resistance ±300m ±600m Measuring current 500µA 250µA 250µA 500µA 250µA resistance transmitter: 3-wire circuit potentiometer: 4-wire circuit max. core 4-wire circuit max. core 2-and 3-wire circuit range: max. core 2-and 3-wire circuit freely programmable within limits steps channels 2sec; channels 4sec order digital filter; filter constant adjustable from 50.0sec Resistance values Measurement time Input filter Input voltage current (Type 954012 Type 954013) Basic range Range Shortest span Range start/end 20mA 20mA 20mA Shortest span Range start/end Measurement time Input filter Features 20mA 20mA +20mA +75mV 100mV -100 +100mV 200mV -500 +500mV +10V Accuracy ±100µV ±100µV ±150µV ±150µV ±1mV ±1mV ±2mV ±10mV ±10mV ±15mV Input resistance freely programmable within limits 999mV 0.01mV steps, from steps) ±20µA ±20µA ±40µA 0.5mA freely programmable within limits 0.1mA steps channels 2sec; channels 4sec order digital filter; filter constant adjustable from 50.0sec Type 954012: adjustable linearizations thermocouples resistance thermometers (for connection transmitters without linearization) burden voltage 2.6V max. burden voltage 2.6Vmax. burden voltage 2.6Vmax. Transducer short-circuit/break Short-circuit1 Thermocouple Resistance thermometer Resistance transmitter Potentiometer Voltage Voltage above Current recognized recognized recognized recognized recognized recognized recognized Break1 recognized recognized recognized recognized2 recognized recognized recognized print head positioned ">>>>>>" appears dot-matrix display. 4-wire circuit: only recognized terminals Outputs (Type 954012) Three open-collector outputs open-collector output signal over/underlimit signal faults chart) 06.02/00355277 JUCHHEIM GmbH 36035 Fulda, Germany Data Sheet 95.4012 Page 4/12 Printing system (Type 954012 Type 954013) Drive Sensitivity Reproducibility Display recording accuracy Print head Print colors Over/underrun Chart speed Paper feed Chart cassette Chart overall width writing width sprocket roller spacing visible diagram length overall length stepper motor 0.2% better referred 100mm writing width 0.25% better referred 100mm writing width Class referred range limits basic ranges print head with penlift function sufficient approx. million dots (depending ambient temperature) Violet, red, black 3-channel printing recorder violet, red, black, green, blue, brown 6-channel printing recorder. Type 954012 color assignment changed will, through setup program. electronically limited 100mm writing width programmable steps 120, 240, 300, 360, 600, 720mm/h stepper motor gearing cassette roll chart fanfold chart (with tear-off edge paper-end switch) roll fanfold chart 120mm 100mm 110mm roll chart: 60mm; fanfold chart: 60mm roll chart: 32m; fanfold chart: Electrical data (Type 954012 Type 954013) Supply (SMPS) 240V +10/-15% 63Hz, AC/DC 63Hz 010, Part March 1994 Electrical safety overvoltage Category contamination Grade Test voltages (type test) with supply 2.3kV 50Hz, 1min; with AC/DC 510V 50Hz, 1min mains supply measurement circuit with supply 1.5kV 50Hz, 1min; with AC/DC 510V 50Hz, 1min mains supply housing 200V 50Hz, 1min between measurement circuits 500V 50Hz, 1min measurement circuits housing electrical isolation between analog inputs Supply voltage sensitivity less than 0.1% range span Power consumption 35VA max. Data buffering More than years through lithium battery days with storage capacitor 25°C ambient temperature. Additional backup EEPROM. Electrical connection rear through plug-in screw terminals, max. conductor cross-section 2.5mm2 1.5mm2 with core sleeves. Type 954012: Setup connector front behind flip-up dot-matrix display Class interference emission industrial requirements immunity interference Housing (Type 954012 Type 954013) Housing type housing door Type 954012/. housing door Type 954013/. Transport mechanism Chart cassette Bezel size Depth behind panel Panel cut-out Housing mounting Ambient temperature range Ambient temperature error Storage temperature range Climatic conditions Operating position Protection Weight Housing front-panel mounting 700, galvanized sheet steel cast zink conductive plastic dissipate electrostatic charges corrosion-resistant chrome-nickel steel plastic (polycarbonate) 144mm 144mm 212mm without screw terminals; 227mm with screw terminals plugged 138+1.0 138+1.0 control panel +50°C 0.2%/10°C +70°C (without print head), +55°C (with print head) relative humidity, condensation normal position: vertical 257) Category front IP54, rear IP20 max. 06.02/00355277 JUCHHEIM GmbH 36035 Fulda, Germany Data Sheet 95.4012 Page 5/12 Operating modes Type 954012 Limit monitoring Eight limit comparators available monitor limits. Limits, differential values (hysteresis), limit comparator functions (lk), texts channels monitored programmed. result monitoring open-collector outputs optional relay module limit state (logic different functions are: Graphic print-out Type 954012 Measurement traces Zoom (plot area) zoom operation, enlarged recording made section full range trace. Presentation range (offset) This parameter used define presentation range trace chart. This assists evaluation, particular traces which close each other which overlap. Peak value recording peak value recording switched each channel. switched-off state, present value channel printed. Since more values measured than printed, minimum maximum values measured between lines printed stored when peak value recording switched These minimum maximum values printed when peak value recording activated. Event traces Eight event traces printed. Limit monitoring (limit comparators) state optional logic inputs thus documented chart. Text printing facilities Type 954012 Type 954013: Time, date Scaling channels Channel numbers Change chart speed Recording start/end text "Power "power off" text Print text check printing system service print Additional text printing facilities Type 954012: limit comparator texts1 (eight underlimit eight overlimit) reports (calculate print minimum, maximum mean values) Eight external texts1 (extra code) binary-linked external texts1 (extra code) Event counter1 (extra code) These texts buffered through queue. long queue full, complete documentation assured. Extra codes Type 954012 RS422/RS485 interface This interface intended communication with higher-level systems system PC). used read measurements, monitor operating states transmit texts values recorder. Logic inputs Eight logic inputs operated either through floating contacts following voltage levels: inactive: active: voltage levels must applied 0.4sec. Functions available include: External start/stop Activate external chart speed Text printing Start/stop external report Start scaling print Increment event counters inhibit Event traces limit state when: measurement limit upper differential. lk8: Type 954013 entire chart width each measurement trace available here. functions zoom, presentation range, peak value recording event traces applicable. lk7, function reversed. Chart speeds LOGOPRINT programmed with four different operating modes chart speed: Normal operation Limit operation measurement goes above/below programmed limits, recorder switches speed which been programmed under "limit operation". External operation signal logic inputs back recorder switches speed which been programmed under "external speed". Timed operation chart speed which operative within programmable time span. Text printing Text printing used comments recorded trace event recording. Type 954012 Printing priorities assigned texts, serve abort criteria during simultaneous text printing requests. Text printing separately configured each text, either time-optimized during continued recording traces. Supply 2-wire transmitter electrically isolated supply 2-wire transmitter available. 45mA external relay module LOGOPRINT equipped with external relay module (eight relay outputs) monitor infringements upper lower limits. relay outputs permanently assigned limit comparators. assignment measurement channels made freely through limit comparator parameter. Contact rating: 250V 50Hz resistive load Type 954013 priorites printing mode strictly defined here. Type 954013 LOGOPRINT junior limit monitoring. Only normal operation possible chart speed. 06.02/00355277 JUCHHEIM GmbH 36035 Fulda, Germany Data Sheet 95.4012 Page 6/12 Display controls Operation configuration Type 954012 Type 954013 recorder eight keys instrument used operating instrument, configure parameters essential operation. 24-character dot-matrix display available indicating monitoring measurements parameters. Type 954012 setup program (accessory) recorder configured using setup program (see diagram, bottom left) more conveniently than using instrument keys. configuration data configured instrument read altered using setup program. further instrument with same configuration, data copied through setup program. configuration data archived data media printed out. addition programming possibilities from keys recorder, setup program offers following extra functions: Setting different print colors Customer-specific linearizations Setting printing mode texts (printing mode: "Overwrite measurement trace" "Interrupt measurement trace") Printing priorities Math logic module editor Various settings managed Setup program (Type 954012) Customer-specific linearizations setup program offers choice between linear, square cube linearization. There calibration points linear square linerarization, calibration points cube linearization. These calibration points used determine coefficients polynomials which defined each section, that even calibration points produce smooth graph. Accuracy: depends shape graph selected linearization. Language Type 954012 Type 954013 language setting (English, German, French) appears print-out dot-matrix display. 06.02/00355277 JUCHHEIM GmbH 36035 Fulda, Germany Data Sheet 95.4012 Page 7/12 Example recording with text print-out Type 954012 Recording start/end text Speed change mm/h through logic input Printing time (with every fourth print-out, current chart speed, programmed instrument name, date printed alternately). selectable logic input closed, count event counter incremented documented together with programmed text. Altogether, event counters available. scaling active channels printed, either pressing (hold down least sec), through logic input. channel number printed selected channel color that individual traces more easily differentiated. Documentation over/underlimit conditions limit comparators. total eight event traces printed out. They used either document state limit comparators, that logic inputs. position event traces chart also programmed. Additional texts (external texts) printed logic input, combination four logic inputs, switched. (10)Print-out report. print-out shows period time which measurements were acquired calculated, well minimum, maximum mean values active channels (including channel name unit). (11)As opposed (5), scaling channels performed alternately programmable spacing. texts which relate logic input only printed extra code logic inputs" (code 259) been implemented recorder. example, traces which were printed above report (10), printed normal mode, i.e. traces share entire chart width 100mm). presentation range selected freely chart each trace. This assists evaluation, particular traces which close another which overlap. traces below report have thus been arranged over sections chart 50mm 100mm). (10) (11) 06.02/00355277 JUCHHEIM GmbH 36035 Fulda, Germany Data Sheet 95.4012 Page 8/12 Connection diagram maximum terminal assignment Rear view 3/6-channel version with plug-in screw-clamp connectors Connection 3/6-channel version Supply label neutral line protective earth Inputs Connector Diagram Analog inputs Type 954012 Type 954013 Connector Thermocouple Resistance thermometer 2-wire circuit Resistance thermometer 3-wire circuit Resistance thermometer 4-wire circuit 06.02/00355277 JUCHHEIM GmbH 36035 Fulda, Germany Data Sheet 95.4012 Page 9/12 Analogue inputs Type 954012 Inputs Diagram Connector Resistance transmitter 3-wire circuit start slider Potentiometer 2-wire circuit Potentiometer 3-wire circuit Potentiometer 4-wire circuit Voltage input Voltage input above Current input 20mA Current input (shunt) ±20mA (when using transducers with changeable internal resistance; extra code "terminal with shunt" required) 06.02/00355277 JUCHHEIM GmbH 36035 Fulda, Germany Data Sheet 95.4012 Page 10/12 Inputs/outputs Type 954012 external relay module Communication with external relay module Connector Diagram Voltage source external 2-wire transmitter 45mA Logic operating inputs Contact operation ROFF 100k HIGH min. pulse length: HIGH 400msec 400msec Voltage operation (inactive) HIGH (active) contact logic input contact logic input Open-collector outputs DOUT1 DOUT4 Umax Imax 100mA Residual voltage DOUT active UDOUTactive 1.2V Communication with higher-level systems RS422/RS485 serial interface Overview electrical isolation 06.02/00355277 JUCHHEIM GmbH 36035 Fulda, Germany Data Sheet 95.4012 Page 11/12 Dimensions Panel-mounting housing Extra code Housing with carrying handle, rubber feet terminal cover, also mains cable with earthed plug Extra code Housing wall mounting. panel-mounting housing fitted carrier swung through 90°. Extra code "TG-35" Portable recorder housing varying applications mobile 06.02/00355277 JUCHHEIM GmbH 36035 Fulda, Germany Data Sheet 95.4012 Page 12/12 Ordering details Basic type 954012 Standard accessories Operating Instructions mounting brackets cable-tie with foot (can released), tension relief sensor leads connected print head, colors (each color available twice) print head, colors roll chart long, fanfold chart pack long Basic type 954013 Basic type extensions Connectors I/II: analog inputs2 analog inputs Code Inputs (programmable) with channels Inputs connector factory-set configuration customer specification Code Consumables Print head items) colors Part 00355244 colors Part 00355255 Roll chart rolls) name, graduation, linear overall length: overall width: 120mm Part 00331497 name, graduation, linear overall length: overall width: 120mm Part 00331499 name, special graduation, linear (marked specified) Fanfold chart packs) name graduation, linear overall length: overall width: 120mm Part 00331490 name, special graduation, linear (marked specified) Inputs (programmable) with channels Inputs connector assigned factory-set configuration customer specification Code RS422/RS485 interface rear assigned RS422, Jbus, MODbus2 RS485, Jbus, MODbus2 Code Supply rear 240V +10/-15% 63Hz AC/DC +0/-0% 63Hz Code Extra codes Code lithium battery buffer (ex-factory) storage capacitor buffer request) logic inputs2, interface2 external relay module (ER8), voltage output2 50mA terminal with shunt items) door with lock (IP54) IP65 seal, wide fixing brackets universal portable housing TG-35 housing with carrying handle housing wall mounting (can swung through 90°) Ordering examples 954012/15-888,888-00-23/020,259 954012 Logoprint analog channels 888,888 channels factory-set RS422 RS485 interface supply lithium battery (ex-factory) logic inputs, interface ER8, voltage output 50mA 2-wire transmitter 954013/15-888,888-00-23/021 954013 Logoprint junior analog channels 888,888 factory-set interface supply storage capacitor Accessories programming2 setup program 3.5" diskettes, multi-lingual interface cable with TTL/RS232 converter Accessory2 external relay module (extra code required) extra codes listed sequence separated comma only Type 954012 06.02/00355277 Other recent searchesXNM1LUG12D6 - XNM1LUG12D6 XNM1LUG12D6 Datasheet Xilinx - Xilinx Xilinx Datasheet XAPP1122 - XAPP1122 XAPP1122 Datasheet Parameterizable - Parameterizable Parameterizable Datasheet Encoder - Encoder Encoder Datasheet Application - Application Application Datasheet TS951-TS952-TS954 - TS951-TS952-TS954 TS951-TS952-TS954 Datasheet SHD3184PA - SHD3184PA SHD3184PA Datasheet LSR4731-PF - LSR4731-PF LSR4731-PF Datasheet LM5000EP - LM5000EP LM5000EP Datasheet LM22670 - LM22670 LM22670 Datasheet D353G - D353G D353G Datasheet 1N4621CSM - 1N4621CSM 1N4621CSM Datasheet
Privacy Policy | Disclaimer |