| Datasheets.org.uk - 100 Million Datasheets from 7500 Manufacturers. |
CPF106C
Top Searches for this datasheetYCL Electronics splitter - YCL Electronics splitter ycl Electronics pots splitter - ycl Electronics pots splitter YCL Electronics - YCL Electronics phone and modem splitter circuit diagram - phone and modem splitter circuit diagram adsl splitter circuit diagram - adsl splitter circuit diagram -"UL 1950" "K.21" -ul1950 -EN60950 -IEC60950 -609 - -"UL 1950" "K.21" -ul1950 -EN60950 -IEC60950 -609 CPF106C - CPF106C CPF106C File Revision System Application Product Type Product Name Date Issued Approved Issued Date RDPS-POTS449 Asymmetric Digital Subscriber Line POTS Splitter CPF106C Dec. 10th, 2002 Gino Hung Design Engineer, R&D_1 gino@ycl.com.tw Roger Manager, R&D_1 roger@ycl.com.tw Electronics Co., Ltd. No.95, Feng Road. Feng Shan City, Kaohsiung, Taiwan, R.O.C. This controlled document property Electronics Co., Ltd. duplication reproduction transmission unauthorized parties without prior written permission Electronics Co., Ltd. prohibited. Data sheet subject change without notice RDPS-POTS449(R0)12/10/2002 SHEET CPF106C Table contents Item Description Introduction Reference Abbreviations Technical requirements 4.1. Schematic 4.2. ZADSL-2 definition 4.3. ZRHF definition 4.4. Electrical specification Environmental condition 5.1. Resistibility overvoltage overcurrents 5.2. Climatic condition 5.2.1. Operating temperature 5.2.2. Storage transport 5.2.3. Operating humidity Reliability conditions 6.1.Thermal shock 6.2. Temperature humidity exposure 6.3. Vibration test Mechanical condition -Page Data sheet subject change without notice RDPS-POTS449(R0)12/10/2002 SHEET CPF106C Introduction: CPF106C splitter module that been specifically designed implement functionality pass filter POTS over ADSL application. Asymmetric Digital Subscriber Line (ADSL) technology dedicated point point public network access technology that allow multiple forms data voice video carried over twisted-pair copper wire local loop between network service provider's(NSP'S) central office customer site local loops created either intra-building intracampus. Best ADSL delivers this high speed performance over existing copper telephone line while allowing traditional voice service coexist without interruption through POTS pass filters. CPF106C integrate pass filter that block high frequency energy from reaching POTS device provide isolation from impedance effects POTS device ADSL. addition these filter will also attenuate wideband impulse noise generated POTS device interruption loop current(e.g. pulse dialing hook hook transfer) Because POTS splitter connects directly subscriber loop media must also provide some protection externally induced line hits faults which could damage attached equipment endanger humans interacting with installed equipment.The circuit protection will provided mostly standard central office line protection means additional protection measures built into pots splitter protect against line overstress which could damage splitter itself. Reference: Ref. Attachment Public Switched Telephone Network Ref. ETSI101 952-1-1 V1.1.1 Specification pass part ADSL/POTS splitters Abbreviations: ADSL POTS Asymmetric Digital Subscriber Line Central Office Customer Premise Equipment. Plain Telephone Service Remote Terminal RDPS-POTS449(R0)12/10/2002 SHEET Data sheet subject change without notice CPF106C Technical requirements 4.1. Schematic following drawing illustrate block diagram this product. 4.2. ZADSL-2 definition: many tests with voice frequencies, ADSL port pass filter terminated with impedance called ZADSL-2. This impedance model represents input impedance ADSL transceiver with seen from pass filter. This substitute circuit shown figure model which shall applied POTS splitter when verifying requirements pass filter. model intended splitter specification context present document. purpose this model impedance splitter specification, requirement input impedance ADSL transceiver. From perspective practical testing, impedance model figure valid case where splitter already contained blocking capacitors third order high pass filter. Figure Schematic diagram impedance ZADSL-2 case where there high pass filter blocking capacitors present splitter unit Data sheet subject change without notice RDPS-POTS449(R0)12/10/2002 SHEET CPF106C 4.3. ZRHF definition: requirements relating ADSL frequencies described present document, terminating impedance ZRHF used terminate TELE LINE ports pass filter. This European harmonized complex impedance ETSI 952-1-1 V1.1.1 subclause 5.2.2 with modification. This network shown figure Figure Schematic diagram impedance ZRHF Data sheet subject change without notice RDPS-POTS449(R0)12/10/2002 SHEET CPF106C 4.4. Electrical specification pass filters shall satisfy following parametric limits with voice terminals Zreal(1) ohms shown this table. following requirements specified single splitter. Splitter parameters General conditions Splitter bandwidth Nominal voice band Billing tone Ringing frequency ADSL band Line Impedance Zreal(1) impedance impedance Modem impedance Operation voltage voice band Nominal signal Billing tone Ringing signal voltage Max. voltage Max. differential Operation current voice band Loop current requirements A-wire B-wire resistances from LINE ohms TELE port; term Isolation resistance, branch-earth VDC; term Mohms resistance Isolation resistance, branch-branch VDC; term Electrical requirements Range values 17.3 1104 ohms ohms ohms ohms mVp-p Vp-p Vp-p 30.2 Vp-p Vrms Vrms with -100 offset 1104 Mohms Voice band requirements Insertion loss Zreal(1) Insertion loss distortion Zreal(1) relative Data sheet subject change without notice RDPS-POTS449(R0)12/10/2002 SHEET CPF106C Splitter parameters Return loss TELE port Zreal(1) Return loss LINE port Zreal(1) Unbalance about earth Zreal(1) Group delay distortion Zreal(1) Electrical requirements Range values 18.05 2000 2000 3400 2000 2000 3400 17.35 2000 18.05 17.35 2000 usec usec usec Frequencies levels pulse metering ADSL band requirements Stop band attenuation Zreal(1) ZRHF Loading ADSL signal path ZRHF Near-end cross talk NEXT 1.104 1.104 1.104 Data sheet subject change without notice RDPS-POTS449(R0)12/10/2002 SHEET CPF106C Environmental condition: 5.1. Resistibility overvoltages overcurrents: splitter comply with requirements ITU-T K.21. 5.2. Climatic conditions: 5.2.1. Operating temperature: Application indoor Long time operation guarantee temperature Short time operation guarantee temperature According 019, class 5.2.2. Storage transport: ambient temperature High ambient temperature According MIL-STD-202 method 5.2.3. Operation humidity: Long time operation guarantee humidity Short time operation guarantee humidity Short time within continuous hours days year Reliability conditions: 6.1. Thermal shock Temperature from cycles (According MIL-STD-202 method 107) 6.2. Temperature humidity exposure /95RH 96hrs (According MIL-STD-202 method 103) 6.3. Vibration test Random vibration frequency 5-500Hz sweep time axis Force 2.4grams (According MIL-STD-202 method 204) Data sheet subject change without notice RDPS-POTS449(R0)12/10/2002 SHEET CPF106C Mechanical condition: Note: Unit tolerances 0.25 Data sheet subject change without notice PHONE LINE RDPS-POTS449(R0)12/10/2002 SHEET Other recent searchesSIGC158T170R3 - SIGC158T170R3 SIGC158T170R3 Datasheet REJ03D0579-0200 - REJ03D0579-0200 REJ03D0579-0200 Datasheet LTC2461 - LTC2461 LTC2461 Datasheet GIO11 - GIO11 GIO11 Datasheet PWM2 - PWM2 PWM2 Datasheet GPE1 - GPE1 GPE1 Datasheet GIO10 - GIO10 GIO10 Datasheet PWM1 - PWM1 PWM1 Datasheet GPE0 - GPE0 GPE0 Datasheet GIO22 - GIO22 GIO22 Datasheet GIO21 - GIO21 GIO21 Datasheet BVH-133H1 - BVH-133H1 BVH-133H1 Datasheet BT139F - BT139F BT139F Datasheet APE2712CGCK - APE2712CGCK APE2712CGCK Datasheet
Privacy Policy | Disclaimer |